Packed-column injector
Removable glass liner for trapping nonvolatile residues
Adapter for on-column injection to wide-bore capillary columns
50 °C to 450 °C in 1 °C increments
1/8-inch fitting
1/4-inch column adapter available
Manual pneumatics – choice of flow controller with headpressure gauge, or flow controller with head-pressure gauge
and digital display of flow
PPC pneumatics – programmed flow or pressure includes
readout which displays pressure or column flow
Split/splitless capillary injector
Split ratio easily adjustable for a wide range of analysis conditions
Charcoal trap in split vent prevents contamination of split valve and lab air
Two choices of liner: 2-mm and 4-mm internal diameter
50 °C to 450 °C in 1 °C increments
Manual pneumatics – pressure regulator (0-60 psig) for digital display of column head pressure. Automatic control of split vent solenoid valve
PPC pneumatics – four software configurable modes:
programmed flow, programmed pressure, programmed
velocity or constant flow. Vacuum compensation
software selectable
PPC pneumatics include automatic control of split vent by split flow or split ratio
Programmable on-column capillary injector
Temperature-programmable inlet
Three-ramps temperature program
Oven tracking mode for simple operation
50 °C to 500 °C in 1 °C increments
Heating rate of 1 °C/min to 200 °C/min or ballistic
Cools down from 380 ˚C to 50 ˚C in less than 6 minutes, while the oven is cooling in the same temperature range and with an FID at 380 ˚C
1/16-inch fitting
Manual pneumatics – choice of flow controller with head-pressure gauge, or flow controller with head-pressure gauge and digital display of flow
PPC pneumatics include readout which displays pressure and column
PSS – programmable split/splitless capillary injector
Temperature-programmable inlet
Large-volume injection of up to 50 µL with autosampler, 150 µL manually
Three-ramps temperature program
Oven tracking mode for simple operation with on-column injection
Split ratio easily adjustable for a wide range of analysis conditions
Three choices of liner available: 1-mm and 2-mm i.d. and on-column
Charcoal trap in split vent prevents contamination of split valve and lab air
50 °C to 500 °C in 1 °C increments
Cools down from 380 ˚C to 50 ˚C in less than 5 minutes, while the oven is cooling in the same temperature range and with an FID at 380 ˚C
Heating rate of 1 °C/min to 200 °C/min or ballistic
1/16-inch fitting
Manual pneumatics – pressure regulator (0-60 psig) for digital display of column head pressure. Automatic control of split vent solenoid valve
PPC pneumatics – four software configurable modes:
programmed flow, programmed pressure, programmed
velocity or constant flow. Vacuum compensation
software selectable
PPC pneumatics include automatic control of split vent by split flow or split ratio
|