Information

 

Potentiostat | Galvanostat 

  • Model : ZIVE MP2C
  • Company : WonATech
  • Country : South Korea

ZIVE MP2C, the outstan dingmulti channel potentiostat/galvanostat/ZRA/FRA, is spin off model from ZIVE MP2 in order to support multiple working electrodes cell with onereference and one counter electrode configuration for sample characterization simultaneously or independently with the complete DC and impedance test. 

Introduction

ZIVE MP2C's each channel is equipped with a frequency response analyzer(FRA) for system as standard and it provides high performance impedance measurements over the frequency range 10uHz to 1MHz.  ZRA(zero resistance ammeter) function can measure max 2 A in galvanic corrosion technique. ZIVE MP2C can be easily upgraded with  adding optional application software package without returning the system to the factory for upgrade.

Application

ZIVE MP2C multichannel electrochemical workstation is ideal for fundamental research in electrochemistry, development and quality assurance of new sensors, corrosion/coatings, electrode material, membrane, conducting polymer, evaluation power device research such as battery materials, fuel cells, super capacitors and solar cells.

 Software (SmartManager)  
ZIVE MP2C multichannel electrochemical workstation use Smart Manager software. You can get more detailed information via above link.

Specification

Specification:

Main system

 

PC communication

USB2.0 High Speed

 

Line voltage

100-240VAC, 50/60Hz, 1Amp

 

Max. channel number

8 independent channels per unit

 

Size/weight

448.7x188.4x535.4mm(WxHxD) / 23.3kg(8ch)

 

Max output power

30Watt

 

System

 

Cell cable

1meter shielded type (Standard)

 

 

Working, reference, counter,

 

 

Working sense

 

Control

DSP with FPGA

 

Calibration

Automatic

 

Data acquisition

2x16bit ADCs (500kHz)for voltage, current

 

ADC

4x 16bit ADCs(250kHz) for auxiliary voltage & temperature reading

 

DAC

2x16bit DAC(50MHz) for bias & scan

 

1X16bit DAC(1MHz) for analog output

 

Filter

4ea (5Hz,1kHz,500kHz, 5MHz)

 

Scan rate

0 – 200V/sec
0-5000V/sec(fast scan)

 

Max. channel No.

32 Channels via USB connection

 

Internal Data Memory

295,000 points

 

LCD Display

DC & EIS mode automatically

 

Power amplifier(CE)

 

Power

24Watt (12V@2A)

 

Compliance voltage

±12V

 

Maximum current

±2A

 

Control speed selection

8ea

 

bandwidth

2MHz

 

Slew rate

10V/usec

 

Potentiostat mode(voltage control)

 

- voltage control

 

Control voltage range

±10V, ±1V, ±100mV

 

Voltage resolution

16 bit per each range

 

Voltage accuracy

±1mV±0.05% of setting

 

Max. scan range

±10V vs. ref. E

 

- current measurement

 

Current ranges

12 ranges(auto/manual setting)

 

20pA ~ 2A

 

(20pA & 200pA with gain)

 

Current resolution

16 bit;

 

60uA,6uA,600nA,60nA,6nA,600pA,

 

60pA,6pA, 600fA, 60fA,6fA,0.6fA

 

Current accuracy

±10pA±0.1% of range(gain x1) >200nA fs

 

Galvanostat mode(current control)

 

- Current control

 

Control current range

Max. ±2A

 

± full scale depending on selected range

 

Current resolution

16 bit;

 

60uA,6uA,600nA,60nA,6nA,600pA,

 

60pA,6pA, 600fA, 60fA,6fA,0.6fA

 

 

 

Current accuracy

±10pA±0.1% of range(gain x1) >200nA fs

 

- Voltage measurement

 

Voltage ranges

10V,1V,100mV

 

Voltage resolution

16 bit; 0.3mV,30uV,3uV

 

Voltage accuracy

±1mV±0.05% of reading

 

Electrometer

 

Max input voltage

±10V

 

Input impedance

2x1013¥Ø||4.5pF

 
 

Bandwidth

>22MHz

 

CMRR

>114db

 

EIS(Internal FRA) for system

 

Frequency range

10uHz ~ 2MHz

 

Frequency accuracy

0.01%

 

Frequency resolution

5000/decade

 

Amplitude

0.1mV ~ 5V rms (Potentiostatic)

 

0.1 ~ 70% f.s(Galvanostatic)

 

Mode

Static EIS:

 

Potentiostatic, galvanostatic, pseudo-galvanostatic, OCP

 

Dynamic EIS:

 

Potentiodynamic, Galvanodynamic

 

Fixed frequency Impedance:

 

Potentiostatic, Galvanostatic, potentiodynamic, galvanodynamic

 

Multisine EIS:

 

Potentiostatic, Galvanostatic

 

Intermittent PEIS/GEIS¡¡

 

Interfaces  for system

 

Auxiliary port

 

 

Digital output

3 (open collector)

 

Digital input

2 (photo coupler)

 

Auxiliary voltage inputs

3 analog Inputs: ±10V

 

 

For measurement of WE vs. CE

 

 

CE vs. RE or other signal

 

Analog output

1 analog output: ±10V

 

 

For stirrer, MFC, RDE etc.

 

Misc.  port

 

 

Sig generator output

1 analog output for FRA output or

 

 

waveform generation output

 

Peripheral communication

I2C to control external devices

 

   

 

Temperature measurement

1 K-type thermocouple input

 

Zero Resistance Ammeter

2nA ~ 2A ranges

 

Software

 

Max steps per experiment

1000

 

Shutdown safety limits

Voltage, current, temperature etc

 

Max. sampling rate

20kHz(50usec)-burst mode/500jHz(2usec) in fast sweep mode

 

Max. sampling time

unlimited

 

Sampling condition

Time, dv/dt, dI/dt, temp etc.

 

PC requirement

 

 

Operating system

WindowsXP SP3/7/8/10

 

PC specification(minimum)

Pentium4, RAM 1GB

 

Display

1600x900 high color

 

USB

High speed 2.0

 

General

 

Dummy cell

One external dummy cell included

 

Thermocouple

1.5meter K-type (option)

 

Auxiliary cable

Option

 

Misc. cable

Option

 

 